# Sharp7Monitor
|
||||
|
||||
Ever needed a simple console program to read some variables from a Siemens S7 PLC?
|
||||
|
||||
Sharp7Monitor is a .NET Console program written in C# that connects to a Siemens S7 PLC (Programmable Logic Controller) and reads specified variables.
|
||||
It displays the variable values in a table format directly in your console. The content of these variables is automatically updated.
|
||||
|
||||
## Usage
|
||||
|
||||
1. **Installation**:
|
||||
- Clone this repository or download the `s7mon.exe` binary.
|
||||
- Ensure you have the necessary dependencies installed (e.g., .NET runtime).
|
||||
|
||||
2. **Invocation**:
|
||||
- Open your terminal or command prompt.
|
||||
- Navigate to the directory containing `s7mon.exe`.
|
||||
- Run the following command:
|
||||
```
|
||||
.\s7mon.exe <IP_Address> <Variable1> <Variable2> ... <VariableN>
|
||||
```
|
||||
Replace `<IP_Address>` with the IP address of your Siemens S7 PLC, and list the desired variables (e.g., `DB2050.Byte1`, `DB2050.Int6`, etc.).
|
||||
|
||||
3. **Output**:
|
||||
- The program will establish a connection to the PLC and continuously display the values of the specified variables in a table format.
|
||||
- The table will automatically update as the variable values change.
|
||||
- Press `Ctrl + C` to exit.
|
||||
|
||||
|
||||
### Command
|
||||
|
||||
`s7mon.exe <IP address> [variables] [OPTIONS]`
|
||||
|
||||
### Arguments
|
||||
|
||||
<IP address> IP address of S7
|
||||
[variables] Variables to read from S7, like Db200.Int4.
|
||||
For format description see https://github.com/evopro-ag/Sharp7Reactive
|
||||
|
||||
### Options
|
||||
```
|
||||
DEFAULT
|
||||
-h, --help Prints help information
|
||||
-c, --cpu 0 CPU MPI address of S7 instance.
|
||||
See https://github.com/fbarresi/Sharp7/wiki/Connection#rack-and-slot.
|
||||
|
||||
-r, --rack 0 Rack number of S7 instance.
|
||||
See https://github.com/fbarresi/Sharp7/wiki/Connection#rack-and-slot.
|
||||
```
|
||||
|
||||
|
||||
### Example Invocation
|
||||
|
||||
```powershell
|
||||
.\s7mon.exe 10.30.110.62 DB2050.Byte1 DB2050.Byte2.4 DB2050.Int6 DB2050.Real34 DB2050.String50.20
|
||||
```
|
||||
|
||||
### Configure Cpu and Rack
|
||||
|
||||
Use `--cpu` and `--rack` parameters to specity the S7 instance to connect to. The required values depend on
|
||||
the S7 you are using and it's configuration. You can find more information in the
|
||||
[Sharp 7 docs](https://github.com/fbarresi/Sharp7/wiki/Connection#rack-and-slot).
|
||||
|
||||
|
||||
|
||||
## Contributing
|
||||
|
||||
Contributions are welcome! If you encounter any issues or have suggestions for improvements, feel free to open an issue or submit a pull request.
|
||||
|
||||
## License
|
||||
|
||||
This project is licensed under the MIT License - see the LICENSE file for details.
|
||||
|
||||
## On the shoulders of giants
|
||||
|
||||
This project is based on great libraries:
|
||||
|
||||
- The [Sharp 7](https://github.com/fbarresi/Sharp7) S7 PLC driver, based on [Snap 7](https://snap7.sourceforge.net/) by Davide Nardella
|
||||
- [Sharp 7 Reactive](https://github.com/evopro-ag/Sharp7Reactive)
|
||||
- [Spectre.Console](https://github.com/spectreconsole/spectre.console)
|
||||
|
||||